AQUAERO 5
Special feature Fan 1”:
Special feature Fan 1”:Special feature “Fan 1”:
Special feature Fan 1”: This connector can alternatively be connected to a
flow sensor. If connected to a flow sensor, select “Sensors” “Flow sensors”
“Flow 2” from the menu and set “Mode” to “Fan 1 = Flow sensor”.
Special feature “Fan 4”:
Special feature “Fan 4”:Special feature “Fan 4”:
Special feature “Fan 4”: This connector can be used for conventional fans or
PWM controlled fans. For PWM fans, select “Outputs” “Fans” “Fan 4”
from the menu and set “Control mode” to “PWM-regulated”.
Pin assignment: Pin 1: GND
Pin 2: 0-12 V
Pin 3: Speed signal
Pin 4: PWM signal (Fan 4 only)
4.4. Connector “PWM 1/2”
4.4. Connector “PWM 1/2”4.4. Connector “PWM 1/2”
4.4. Connector “PWM 1/2”
Pulse width modulated 12 V outputs, maximum current load 1 A, carrier
frequency 15 kHz.
Pin assignment: Pin 1: VCC
Pin 2: GND
4.5. Connector „IR-LED
4.5. Connector „IR-LED4.5. Connector „IR-LED“
4.5. Connector „IR-LED
Connector for an infrared transmitter LED. This output is not yet functional
with firmware version 1010 and will be activated with an forthcoming
firmware update.
Pin assignment: Pin 1: GND
Pin 2: +12 V
Pin 3: Signal
Pin 4: +5 V
4.6. Connector “aquabus 1/2”
4.6. Connector “aquabus 1/2”4.6. Connector “aquabus 1/2”
4.6. Connector “aquabus 1/2”
Connectors for communication with other devices from Aqua Computer. The
aquaero 5 features one „low speed“ (aquabus 1) and one „high speed“
(aquabus 2) port.
Products compatible to the “low speed” port:
multiswitch USB
tubemeter USB
Products compatible to the “high speed” port:
aquastream XT
poweradjust 2 USB (Firmware 1003 or higher)
© 2011 Aqua Computer GmbH & Co. KG - 6 -
Gelliehäuser Str. 1, 37130 Gleichen
Page view 5